Product Description

SUWI-120 SERIES MULTIFUNCTION SUBSTATION TEST SET

HIGHLIGHTS

   - Multifunctional test device

   - Relay Timing Tests

   - Turns Ratio Tests

   - Contact Resistance Tests

   - 3Φ Circuit Breaker Timing Tests

SUWI-120 series stands as a versatile testing instrument meticulously crafted to evaluate the performance of power and control apparatus within substations. It encompasses an array of essential tests, including the precise assessment of Relay Timing, the determination of a Transformer’s Turns Ratio, the scrutiny of Circuit Breaker Contact Resistance and Timing, as well as the examination of MCBs, among other critical functions. This all-encompassing substation testing device has earned the name SUWI, from our belief in its skills as a Substation Wizard.

 

 

RELAY TIMING MEASUREMENT

The SUWI instrument can automatically test over-current, over-voltage, directional overcurrent relays and frequency control relays. SUWI has an adjustable output current up to 110A AC / 120A DC and an adjustable output voltage to 150V AC / 220V DC. It has four universal input modules.

 

TURNS RATIO MEASUREMENT

Employing elements of performance tests specified in the ANSI/IEEE C57.12.90 standard, the instrument performs transformer ratio measurements to a precision of 0.08 % across a ratio range of 0.8 to 10,000.

SUWI also measures phase angle and polarity, and it can generate 1V, 4V, 10V, 40V and 100V AC test voltages to facilitate the measurement of the turns ratio for current, voltage and power transformers.

 

CONTACT RESISTANCE / LOW RESISTANCE MEASUREMENT

SUWI has an adjustable output DC current up to 120 Amps which facilitates the measurement of contact resistance of a circuit breaker, a shunt or disconnector. SUWI-120 can measure resistance up to 5 Ω, with a resolution of 0.01 μΩ.

 

CIRCUIT BREAKER TIMING

Contact Timing Tests are performed to determine a breaker’s contact performance against its manufactured specifications. The timing for a breaker’s operation such as OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN and OPEN-CLOSE-OPEN are measured for all three-phases simultaneously. SUWI can perform 3-phase circuit breaker timing test cycles as described above along with coil current measurements using internal and external trigger inputs.

 

TECHNICAL SPECIFICATIONS

 Measurement       Parameters Relay Timing Tests (over current relays, over voltage relays,    directional over current relays, frequency control relays);
Turns Ratio Measurement, Phase Angle, Polarity, Ratio Error(%);
Contact Resistance/Low Resistance Tests (Circuit breaker contact resistance and shunt resistance)
Circuit breaker timing test (3-phase circuit breaker timing tests; open, close, open-close, close-open, open-close-open timings, coil current measurement, internal and external trigger operations)

 

 

PROTECTION RELAY TIMING MEASUREMENT FEATURES

  Current Outputs   Up To 110 A AC (magnitude and frequency adjustable)
  Up to 120 A DC
  Voltage Outputs   150 V AC (magnitude and frequency adjustable)
  220 V DC
  Universal Input Modules   4 input modules; Binary wet/dry
  Up to 300 V AC/DC voltage measurement

 

TURNS RATIO MEASUREMENT FEATURES

  Ratio Measurement Modes   CT Mode
  PT Mode (Single-Phase and Three-Phase)
  Test Voltages   CT Mode: 1 V and 4 V;
  PT Mode: 1, 4, 10, 40 & 100 V
  Ratio Range   0.8 – 10,000

 

CONTACT RESISTANCE/LOW RESISTANCE MEASUREMENT FEATURES

  Measurement Modes   Static Resistance Measurement
  Auto Test Mode   Yes
  Test Current   Up to 120 A DC
  Measurement Range   Up to 5 Ω

 

CIRCUIT BREAKER TIMING MEASUREMENT FEATURES

Measurement Parameters    Contact Timing (O, C, O-C, C-O & O-C-O);
  Coil Current Measurement, Internal and External Trigger  Operations
 Timing Windows   1s, 10s, 20s
 Timing Accuracy   0.05% rdg ± 0.1 ms
 Contact detection   Yes
 Trigger input voltage   24 – 300 V DC or ACpeak
 Breaker Initiate Capacity   20 A, 300 V DC or ACpeak
 Initiate current reading range   0 – 20A DC, 5 kHz

 

GENERAL FEATURES

  Power Supply   100-240 V, 47-63 Hz
  Internal Memory   Yes
  Communication   USB 2.0/1.1 Standard-B, Ethernet
  PC Software   DMP Software
  Display   7-inch IPS 1024×600 pixel touch panel display
  Dimensions   (16.9 × 12.9 × 9.3)” (429 x 328 x 236) mm
  Weight   10.70 kg
  Temperature   Working: -10 °C to +60 °C; Storage: -30 °C to +70 °C
  Humidity   95% RH Non-condensing
  Protection Class   IP67 (case closed)
  Included in the Package     4x 5m Input Cable Set (Red & Black), 1x 5m V OUT Cable Set (Red & Black), 2x 3m Contact Cable Set (Blue & White), 1x 2.5m I OUT Cable Set (Black & Red), Power Cable, Ground Cable, Ethernet Cable, USB flash drive, Instruction Manual (Soft Copy), DMP Software, Cable Bag

Specifications are valid at/under 25 °C temperature. *Content subject to change without notice.